Benui load cell
Load cell |  Weighing Scale |  Weighing Accessories
Aluminum alloy load cell/ Min sensor AM672
Aluminum alloy load cell/ Min sensor AM672
Features: Aluminum-alloy load cell/senso; Colourless anodized; Hermetically sealed with glue to IP65. Applications: Electronic counting scales, platform scales etc.

Outline Size
Aluminum alloy load cell/ Min sensor AM672
Electrical Connetion



Aluminum alloy load cell/ Min sensor AM672


It uses 4-core shielded cable(φ5x2500mm). The length of the cable can be adjusted according to clients' request, but we suggest to use this standard length to ensure the output precision.

Parameters:

Rated load: 200, 300(kg)

Precision: C2

Size: 210x45x50(mm)

Thread hole: 6-M8

Comprehensive error: 0.02%F.S

Insulation resistance: ≥5000MΩ(100VDC)

Rated output: 2±0.1mV/V

Excitation voltage: 9VDC~12VDC

Non-linearity: 0.02%F.S

Compensated temp.range: -10℃~+40℃

Hysteresis: 0.02%F.S

Use temp.range: -20℃~+60℃

Repeatariy: 0.01%F.S

Temp.effect on zero: 0.02%F.S/10℃ & 0.03%F.S/10℃

Creep: 0.02%F.S/10min

Temmp.effect on span: 0.02%F.S/10℃

Zero balance: ±2%F.S

Safe overload: 120%

Input resistance: 405±10Ω

Ultimate overload: 150%

Output resistance: 350±3Ω

Defense class: IP65