Benui load cell
Load cell |  Weighing Scale |  Weighing Accessories
Universal Force Transducer (Tension & Compression) GS513

  
Dimension:

Unit: mm

Cap/Size C H T
100~200kg 65 51 M10×1.5
250~500kg 105 64 M12×1.75
1~3t 105 64 M20×1.5
5t 120 92 M24×2
10~20t 120 92 M30×2
25~30t 138 92 M36×3
50t 180 124 M52×3

Description:
▲Tension & compression fittings.
▲Standardised output for multiple cell systems.
▲Instrumentation / system calibration.
▲6-core cable connection.
 ◆Safe overload 150% Rated Capacity. Ultimate load 300% Rated Capacity.
Combined error, considering non-linearity & hysteresis as deviation from best straight line, from ZO to FSO.
 ◆Correct mounting of the load cell is essential to achieve optimum performance
 ◆Calibration void if cable length is altered.

Technical Parameter:

Rated Load 100/200/250/500kg,1/3/5/10/20/30/50t
Sensitivity (2.0±0.1%)) mV/V
Combined Error ±0.03%F.S
Creep Error(30min) ±0.03% F.S
Zero Balance ±1% F.S
Temp. Effect On Zero: ±0.05% F.S/10℃
Temp. Effect On Span: ±0.05% F.S/10℃
Input Resistance: 750±5Ω
Output Resistance: 701±2Ω
Insulation Resistance: ≥5000MΩ
Operating Temperature Range -30~+70℃
Maximum Safe Over Load: 150%F.S
Ultimate Over Load: 200%F.S
Recommend Excitation Voltage: 10~12V DC
Maximum Excitation Voltage: 15V DC
Sealing Class: IP67/IP68
Element Material: Alloy Steel/ Stainless Steel
Cable: Length=L: 3m(0.1~5t),12m(10~50t)
Citation GB/T7551-1997/ OIML R60
Mode Of Connection Red(Input+),Black(Input-),Green(Output+),White(Output-)

Note: Order Codes :
GS513C – Calibrated in compression only
GS513T – Calibrated in tension only
GS513TC –Universal calibration

Copyright©,NingBo Benui Electric company. All Rights Reserved   link | Site Map | Load Cells | weighing scale