Inquiry Basket > > > > Inquiry Now
product detail
  • Product Name: Tension Load Cell GLA
  • Model No: Tension Load Cell GLA Special for crane scale
  • OR
Description:

Tension Load Cell GLA Special for crane scale

Model

GLA

Rated load

0.5,1,2,3,5,10,20t,30t

Description

The design is all-in-one, high precision, easy installation, super load. Can be used with international standard hook and flying rings.

Accuracy class

C2/C3

Changeable

usual,high tempe,digital

Sensitivity

2±0.1%mV/V

Load type

pull

Protection

IP67/68

Temperature

-30~70ºC

Use range

Can be used in crane scale.

Packaging

(carton)

Rated load

1~5t

7.5~10t

15~20t

Net.(kg)/ctn

2.8kg/4pcs/ctn

3.9kg/4pcs/ctn

9.2kg/2pcs/ctn

Description

Capacities (Emax)
1 ,2, 3,5 ,7. 5, 10 ,20t ,30t

Output:
Analog: 2.0mV /V.
Digital: 30,000 or 100,000d.

Accuracy
3000d OIML R60.

Material of load cell block:
Alloy steel o r stainless steel.

Approvals
OIML R60 C erti fica te
Accuracy class C3.
Vmin= Em ax/15000

Sealed to IEC 529.
Classification IP67 or IP68.Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1m head of water.

Dimensions
(In mm . 1mm = 0.03937 inches)

Model: GLA Specification
Item Parameter C2 C3 UNIT
Rated load (Emax): 1,2,3,5,7.5, 10,2,30,40, 50,60 t
Maximal numbers of load cell verification Intervals(Nlc): 2000 3000 d
Minimum load cell verification intervals(Vmin) 0.02 0.01 % of rated l oad
Sensitivity(Cn): 2±0.1% mV/V
*Combined error: 0.027 0.015 ±% o f rated output
Temperature effect on sensitivity (Tkc): 0.0024 0.0012 ±% of rated output/
Temperature effect on zero balance (Tk0): 0.002 0.0008 ±% o f rated output/
Zero balance: 1.0 ±% o f rated output
Input resistance(Rlc): 385 ±5 Ω(O hms )
Output resistance(R0): 351 ±2 Ω(O hms )
Insulation resistance: ≥5000 MΩ(M ega-Ohms)
Safe overload: 150 % of rated c apability
Ultimate overload: 300 % of rated c apability
Operating temperature range: -30~ 70/-20~ 160 ℃/ ℉
Recommend excitation: 9 V (AC or DC)
Maximum excitation: 18 V (AC or DC)
Material of elastomer: alloy steel / stainless steel
Protection class: IP67/IP68
Cable Ф6       13m (10~30t) / 18m (40~60t)
Citation: OIML R60 / GB7551-1997
The data for deviation of sythesis error, Tko,Tkc are typicl values. The sum of these data meets the requirements according to OIML R60.

Circuit Diagram

Electrical Termination
1~3t:3m. >=7.5:6m.
Excitation: black -Ve, red Ve
Signal: white -Ve, green Ve
Screen: yellow
Diameter: Ф6

Note:
Do not change length of 4
core cables, or else it will
effect sensitivity of load cell.