Benui load cell
Load cell |  Weighing Scale |  Weighing Accessories
Compression Load Cell QS Double shear beam load cell
Compression Load Cell QS
Compression Load Cell QS

Model

QS

Rated load

10,20,30,40,50t

Description

The load cell can be used in truck scale, railway scale, blending scale and special scale  of all kinds of weighing apparatus. High precision and reliability. Easy installation against strong impact.

Accuracy class

C2/C3

Changeable

usual,digital

Sensitivity

2±0.1%mV/V

Load type

press

Protection

IP67/68

Temperature

-30~70℃

Optional

The load cell can be produced into analog load cell, digital load cell, wireless load cell, high temperature load cell.
The material: alloy steel, stainless steel

Use range

Can be use to all kinds of weighing apparatus, The load cell can be used in truck scale, railway scale, blending scale and special scale.

Packaging

(carton)

Rated load

10~30t

40~50t

Net.(kg)/CTN

16.2kg/1pcs/ctn

25.6kg/1pcs/ctn

Measurement/Weight:0.41×0.21×0.21 m / 0.7kg


Compression Load Cell QS

Compression Load Cell QS

Description

Capacities (Emax)
10,20,30,40,50t.

Output:
Analog: 2.0mV /V.
Digital: 30,000 or 100,000d.

Accuracy
3000d OIML R60.

Material of load cell block:
Alloy steel o r stainless steel.

Approvals
OIML R60 C erti fica te
Accuracy class C3.
Vmin= Em ax/15000

Sealed to IEC 529.

Classification IP67 or IP68.Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water.

Dimensions
(In mm . 1mm = 0.03937 inches)

Compression Load Cell QS

Model: QS Specification

Item\ Parameter C2 C3 UNIT
Rated load (Emax): 10,20,25,30,40,50,60 t
Maximal numbers of load cell verification Intervals(Nlc): 2000 3000 d
Minimum load cell verification intervals(Vmin) 0.02 0.01 % of rated l oad
Sensitivity(Cn): 2.0+/-0.1% mV/V
*Combined error: 0.027 0.015 +% o f rated output
Temperature effect on sensitivity (Tkc): 0.0024 0.0012 ⊥% of rated output/
Temperature effect on zero balance (Tk0): 0.002 0.0008 +% o f rated output/
Zero balance: 1.0 ⊥% o f rated output
Input resistance(Rlc): 775±5 Ω(O hms )
Output resistance(R0): 701±2 Ω(O hms )
Insulation resistance: ≥5000 MΩ(M ega-Ohms)
Safe overload: 150 % of rated c apability
Ultimate overload: 300 % of rated c apability
Operating temperature range: -30~+ 70/-20~+ 160 ℃/ ℉
Recommend excitation: 12 V (AC or DC)
Maximum excitation: 24 V (AC or DC)
Material of elastomer: alloy steel / stainless steel
Protection class: IP67/IP68
Citation: OIML R60 / GB7551-1997
The data for deviation of synthesis error, TKo, TKc are typical values. The sum of these data meets the requirements according to OIML R60.


Compression Load Cell QS

Circuit Diagram

Electrical Termination
4 Core cable standard lengths:
<=30t: 12.0 m, >=40t: 18m.
Excitation: black -Ve, red +Ve
Signal: white -Ve, green +Ve
Screen: yellow
Diameter: Ф6

Note:
Do not change length of 4
core cables, or else it will
effect sensitivity of load cell.