Product Characteristics:
GS213 Load cell with thin wall and blind hole structure. High precision, strong anti-deflective loading. Good shock resistance, simple to install. Moisture proof sealed, used in various crane scale.

Unit: mm
Cap/Size |
L1 |
L2 |
L |
H |
B |
M |
3t |
26 |
55 |
157 |
55 |
45 |
M24×3 |
5t |
42 |
71 |
206 |
66 |
45 |
M36×3 |
10t |
42 |
78 |
206 |
72 |
64 |
M42×3 |
20t |
50 |
100 |
248 |
92 |
65 |
M52×3 |
50t |
80 |
144 |
362 |
136 |
90 |
M80×6 |
Technical Parameter:
Rated load |
5/10/20/30/40/50t |
Sensitivity |
(1.5±0.1%) mV/V |
Combined error |
±0.03% F.S |
Creep Error(30min) |
±0.03% F.S |
Zero balance |
±1% F.S |
Temp. effect on zero: |
±0.02% F.S/10℃ |
Temp. effect on Span: |
±0.02% F.S/10℃ |
Input resistance: |
750±5Ω |
Output resistance: |
702±2Ω |
Insulation resistance: |
≥5000MΩ |
Operating Temperature Range |
-30~+70℃ |
Maximum safe over load: |
150%F.S |
Ultimate over load: |
200%F.S |
Recommend excitation voltage: |
10~12V DC |
Maximum excitation voltage: |
15V DC |
Sealing Class: |
IP68 |
Element material: |
Alloy Steel |
Cable: |
Length=L:0.5m |
Citation |
GB/T7551-1997/ OIML R60 |
Mode of Connection |
Red(Input+),Black(Input-),Green(Output+),White(Output-)t-) |