Benui load cell
Load cell |  Weighing Scale |  Weighing Accessories
Compression Load Cell GS425


Unit: mm
Cap/Size A B C D E M F
0.5-3klb 115.8 89.6 15.9 6.4 73.2 1/2-20 22
5-10klb 150.9 89 34.3 9.4 73.2 1-14 32
20-30klb 215.9 127 63.5 13.5 90.8 3/2-12 51
50-100klb 290.6 165.1 76.2 13.5 112 12-12 70

Product Characteristics:
GS425 load cell column type, hermetically sealed structure, Compression, IP68, dual bridge optional; Simple to install, easy to use; Suitable for truck scale, railroad scale and other special scale.

Technical Parameter:

Rated load 0.5/1/2/3/5/10/20/30/50/100klb
Sensitivity (2.0±0.1%) mV/V
Combined error ±0.03% F.S
Creep Error(30min) ±0.02% F.S
Zero balance ±1% F.S
Temp. effect on zero: ±0.02% F.S/10℃
Temp. effect on Span: ±0.02% F.S/10℃
Input resistance: 750±5Ω
Output resistance: 702±2Ω
Insulation resistance: ≥5000MΩ
Operating Temperature Range -30~+70℃
Maximum safe over load: 150%F.S
Ultimate over load: 300%F.S
Recommend excitation voltage: 10~12V DC
Maximum excitation voltage: 15V DC
Sealing Class: IP68
Element material: Alloy Steel / Stainless Steel
Cable: Length=L:15m
Citation GB/T7551-1997/ OIML R60
Mode of Connection Red(Input+),Black(Input-),Green(Output+),White(Output-)