You are here : Home > Products > Load Cell > Compression Load Cell > GS426


| Cap/Size | A | B | C | H | M | SR1 | SR2 |
| 3-30t | 54 | 42 | 13 | 135 | M10 | 200 | 250 |
| 50-100t | 89 | 64 | 30 | 190 | M12 | 300 | 300 |
| 150-200t | 115 | 90 | 20 | 210 | M16 | 400 | 400 |
| 300t | 121 | 110 | 20 | 240 | M16 | 400 | 400 |
| 500t | 180 | 130 | 25 | 350 | M12 | 600 | 600 |
Technical parameter:
| Rated load | 3/5/10/20/3050/100/150/200/300/500t |
| Sensitivity | (2.0±0.1%) mV/V |
| Combined error | ±0.1% F.S |
| Creep Error(30min) | ±0.02% F.S |
| Zero balance | ±1% F.S |
| Temp. effect on zero: | ±0.02% F.S/10℃ |
| Temp. effect on Span: | ±0.02% F.S/10℃ |
| Input resistance: | 750±5Ω |
| Output resistance: | 702±2Ω |
| Insulation resistance: | ≥5000MΩ |
| Operating Temperature Range | -30~+70℃ |
| Maximum safe over load: | 150%F.S |
| Ultimate over load: | 300%F.S |
| Recommend excitation voltage: | 10~12V DC |
| Maximum excitation voltage: | 15V DC |
| Sealing Class: | IP67/IP68 |
| Element material: | Alloy Steel / Stainless Steel |
| Cable: | Length=L:13m |
| Citation | GB/T7551-1997/ OIML R60 |
| Mode of Connection | Red(Input+),Black(Input-),Green(Output+),White(Output-) |