You are here : Home > Products > Load Cell > Compression Load Cell > SK504

Unit: mm
Cap./Size |
1t |
2.2t |
4.7t |
10t |
15t |
22t |
33t |
47t |
68t |
100t |
150t |
220t |
330t |
470t |
| φA | 49 |
49 |
49 |
74 |
75 |
75 |
95 |
130 |
130 |
150 |
150 |
22.5 |
225 |
270 |
| φB | 20 |
20 |
20 |
30 |
30 |
30 |
40 |
60 |
60 |
70 |
70 |
100 |
100 |
120 |
| φC | 60 |
60 |
60 |
75 |
75 |
75 |
95 |
130 |
130 |
150 |
151 |
22.5 |
225 |
270 |
| H | 43 |
43 |
43 |
50 |
50 |
50 |
65 |
75 |
85 |
90 |
100 |
130 |
145 |
170 |
| J | - |
- |
- |
7 |
7 |
7 |
7 |
7 |
7 |
7 |
7 |
10 |
10 |
10 |
| K | 7.5 |
7.5 |
7.5 |
6.5 |
6.5 |
6.5 |
10 |
14 |
14 |
16 |
16 |
24 |
24 |
28 |
| R | 15 |
15 |
15 |
25.4 |
25.4 |
25.4 |
50 |
60 |
- |
- |
- |
- |
- |
- |
| Deep | 2.2 |
2.2 |
2.2 |
3.3 |
3.3 |
3.3 |
3.3 |
5.1 |
- |
- |
- |
- |
- |
- |
Technical Parameter:
Rated load |
1/2.2/4.7/10/15/22/33/47/68/100/150/220/330/470t |
Sensitivity |
(2.0±0.01%) mv/v |
Combined error |
±0.02% F.S |
Creep Error(30min) |
±0.02% F.S |
Zero balance |
±1% F.S |
Temp. effect on zero: |
±0.02% F.S/10℃ |
Temp. effect on Span: |
±0.02% F.S/10℃ |
Input resistance: |
750±5Ω |
Output resistance: |
702±2Ω |
Insulation resistance: |
≥5000MΩ |
Operating Temp. Range |
-30~+70℃ |
Maximum safe over load: |
150%F.S |
Ultimate over load: |
200%F.S |
Recommend excitation: |
10~12V DC |
Maximum excitation: |
15V DC |
Sealing Class: |
IP67/IP68 |
Element material: |
A:Alloy Steel, SS:Stainless Steel |
Cable: |
Length=L:13m |
Citation |
GB/T7551-1997/ OIML R60 |
Mode of Connection |
Red(Input+),Black(Input-),Green(Output+),White(Output-) |