Model

SQA

Rated load

0.5,1,2,2.5

Description

The load cell can be used in forklift scale, floor scale, blending scale, low platform scale. High precision, super anti-side force, flat design, equipped with many indenters.

Accuracy class

C2/C3

 

 

Sensitivity

2±0.2%mV/V

Load type

pull/press

Protection

IP67/68

Temperature

-30~70ºC

Optional

The load cell can be produced into analog load cell, digital load cell, wireless load cell.
The material: alloy steel, stainless steel

Use range

The load cell can be used in forklift scale, floor scale, blending scale, low platform scale.

Packaging

(carton)

Rated load

0.5~2.5t

Net.(kg)*a box

1kg/8pcs/ctn

Measurement/Weight:0.41×0.21×0.21 m/ 0.7kg


Single Point Load Cell SQA

Main Technical data

 (Unit)

Technical quota

Rated Load

t

0.5,1,2,2.5

Sensitivity

mV/V

2.0±0.002

Total error

%F.S

±0.03

Creep(30mins)

%F.S

±0.02

Zero balance

%F.S

±1

TCO

%F.S/10℃

±0.02

TC SPAN

%F.S/10℃

±0.02

Input resistance

Ω

380±10

Output resistance

Ω

353±2

Insulation resistance

Ω

≥5000M

Operating Temp Range

-30~+70

Safe load limit

%F.S

120

 Lateral load limit

%F.S

150

Recommend excitation

V DC

10~12

 Maximum excitation

V DC

15

Protection Class

IP68

 

Material

Alloy Steel/Stainless steel

Cable  

Dimeter:φ5.2;Length:3m