Benui load cell
Load cell |  Weighing Scale |  Weighing Accessories
Single Point Load Cell SQB

Shear Beam Load Cell
Single Point Load Cell SQB

Dimensions:


Unit: mm

Cap.Size

L

L1

L2

L3

L4

B/H1

H

D1

ΦD

M

0.1~0.5t

130

54

12.7

25.4

76.2

32

34

12.8

13.5

M12

1~3t

130

54

12.7

25.4

76.2

32

34

12.8

13.5

M16

3~5t

171.5

77

19.1

38.1

95.3

38

40

20

20

M18x1.5


Product Characteristics:
SQB series is single shear beam. One end of the load cell is fixed, another loaded and rocker pressure head transfers force. Easy installation and it is suitable for floor scale, automobile test facilities, hopper scale and other electronic weighing devices.

Technical Parameter:

Rated Load

0.1/0.2/0.3/0.5/1/2/3/5t

Sensitivity

(2.0±0.1%) mV/V

Combined Error

±0.02% F.S

Creep Error(30min)

±0.02% F.S

Zero Balance

±1% F.S

Temp. Effect On Zero:

±0.02% F.S/10℃

Temp. Effect On Span:

±0.02% F.S/10℃

Input Resistance:

385±5Ω

Output Resistance:

352±2Ω

Insulation Resistance:

≥5000MΩ

Operating Temperature Range

-30~+70℃

Maximum Safe Over Load:

150%F.S

Ultimate Over Load:

250%F.S

Recommend Excitation Voltage:

10~12V DC

Maximum Excitation Voltage:

15V DC

Sealing Class:

IP67/IP68

Element Material:

Alloy Steel, Stainless Steel

Cable::

Length=L: 3m(0.1~3t),5m(5t)

Citation:

GB/T7551-1997/ OIML R60

Mode Of Connection:

Red(Input+),Black(Input-),Green(Output+),White(Output-)