You are here : Home > Products > Load Cell > Tension Load Cell > GLC

Model |
GLC |
Rated load |
2.5,5t |
|
Description |
The load cells can be used in the Hook scale, Hopper scale, Packing scale, overload limiter, crane scale. The design is all-in-one, high precision, easy installation, super load. Can be used with international standard hook and flying rings. |
|||
Accuracy class |
C2/C3 |
|
|
|
Sensitivity |
2±0.2%mV/V |
Load type |
pull |
|
Protection |
IP67/68 |
Temperature |
-30~70℃ |
|
Optional |
The load cell can be produced into analog load cell, digital load cell, wireless load cell. |
|||
Use range |
Can be used in The load cell can be used in the Hook scale, Hopper scale, Packing scale, overload limiter, crane scale. |
|||
Packaging
(carton) |
Rated load |
|||
Net.(kg)/CTN |
||||
Measurement/Weight: |
||||

Main Technical data |
(Unit) |
Technical quota |
Rated Load |
t |
2.5,5 |
Sensitivity |
mV/V |
2.0±0.002 |
Combined Error |
%F.S |
±0.05 |
Creep (30mins) |
%F.S |
±0.03 |
Zero Balance |
%F.S |
±1 |
Zero Temperature Effect |
%F.S/10℃ |
±0.03 |
Output Temperature Effect |
%F.S/10℃ |
±0.03 |
Input Impedance |
Ω |
380±10 |
Output Impedance |
Ω |
352±2 |
Insulated Resistance |
Ω |
≥5000M |
Working Temperature Scope |
℃ |
-30~+70 |
Safe Load |
%F.S |
120 |
Utmost Load |
%F.S |
150 |
Recommended Drive Voltage |
V DC |
10~12 |
Maxi Drive Voltage |
V DC |
15 |
Airproof Rank |
IP68 |
|
Material |
Alloy Steel/ Stainless steel |
|
Cable |
Diameter:φ6;Length:1m |
|