Benui load cell
Load cell |  Weighing Scale |  Weighing Accessories
The Software For Digital Load Cell



Ò»¡¢System composition, Structure£º


Note£ºDigital weighing system, there are two options£º
1¡¢The traditional way: connected digital devices, features: simple and practical£»
2¡¢Connect the computer, features: powerful, intelligent high degree of weighing data network share can be achieved.
3¡¢Digital sensor can connect up to 16pcs.

¶þ¡¢System Features
1¡¢Powerful and rich, to meet the needs of customers£»
2¡¢Able to self-diagnose failures and real-time display of real-time status of each load cell£»
3¡¢System, adjustment and verification by the keyboard input without having to manually adjust the Junction Box£»
4¡¢Using RS485/232 standard interface, the transmission distance up to 1.2 km£»
5¡¢Can contact not less than 16 digital load cell£»
6¡¢Output signal normalized, consistency is good, easy to swap and applications, sensors, meters, weighing management software replacement without re-calibration.
7¡¢Weighing management software, human-machine interface is friendly, simple operation, data query, statistics, backup, maintenance ranging.
8¡¢Intelligent level of high-tech, technically guarantees the occurrence of misuse and to prevent staff fraud£»
9¡¢Optional uninterruptible power supply to ensure the continued operation after power failure (meter can be equipped with batteries, computer with UPS).

Èý¡¢System Accessories Application Notes
1¡¢Digital Load Cell

The company is equipped with a digital sensor£ºBridge Series£¨QS£©¡¢Column Series£¨GS409¡¢GS419¡¢GS406£©¡¢SQB Series£¨SQB£©¡¢SB Series£¨SB£©Etc.
Digital load cells are conducted before delivery number (address) and internal code values (sensitivity) calibration, to installation, commissioning is simple, quick. Digital sensor installation method and installation of a high degree with the analogue, but the installation must be installed to record the specific scale angle load cell.

Digital Load Cell Specifications£º

item unit  
Min Load Cell Verification Interval (Vmin)  % of Emax 0.0200
Sensitivity(Cn) Digit(d) 1000000
Sensitivity Tolerance % ≤0.0100
Temperature Effect On Sensitivity (Tkc) Temperature Effect On Zero Signal (Tk0) % of Cn/10K ≤0.0120 ≤0.0145
Hysteresis Error (Dhy) Non-Linearity(Dlin) Creep(Dcr)30min % of Cn ≤0.0120 ≤0.0080 ¡Ü0.0080
Reference Excitation Voltage (Uref) Norminal Range Of Excitation Voltage(BU) V(DC) 8 7~15
Current Consumption mA 35
A/D Resolution Bit 24£¨at 1 Hz£©
Measuring Rate /sec 80
Filter Mode 0 Filter Mode 1 HZ 3~0.05 8~3
Communication Mode   RS485/2-wire
Baud Rate Baud 9600
Number Of Bus Addresses Max 64
Nominal Temperature Range (BT) Service Temperature Range(Btu) Storage Temperature Range(BU) ℃[°F] -10~+40 -20~+70 -50~+80
Limit Load (EL) % of Emax 150
Breaking Load(ED) % of Emax >300
Protection Class   IP67/68
Material Alloy Steel/ Stainless Steel

2¡¢Set Box£¨Junction Box£©
And analog-style look and feel consistent, but do not have the regulatory function, using aluminum (die-casting molding process) or stainless steel (die forming process) production, compact structure, good sealing, specifications are 4,6,8,10,12 line..   Attachment: Photo

3¡¢
RS485/232 Converter£¨in our website product name: ATC108£©  
The company is equipped with RS485/R232 converter model ATC-108, the outline:

¢Ù¡¢ATC-108 are optical isolated interface converter is compatible with RS -232C, RS-422, RS-485 standard, the ability to single-ended RS-232 signals are converted to a balanced differential RS-232 or RS-485 signal, the built-in optical isolators and DC / DC DC converter, able to provide 3500V isolation voltage, fast transient voltage suppressor (TVS) can effectively suppress lightning and ESD, provide each line of the lightning surge protection power of 1000W to be effective in the to prevent lightning strikes, and a total of interruption

¢Ú¡¢RS-232 interface port via a standard DB9 female head and PC, laptop computer connections, RS-232, RS-485 terminal through the convenience of the seven terminals with a plug connection.

¢Û¡¢ATC-108 optical isolation interface converter internal circuitry to automatically sense the direction of data flow and automatically switch to enable to control, to facilitate the composition of an RS-485 network without the need for any handshake signal, this RS-485 enable control is completely transparent, without losing the previous work based on the RS-232 to make any software modifications.

¢Ü¡¢ATC-108 optical isolation interface converter for point to point, multipoint communication to provide reliable connectivity, multipoint allows connect up to 32 RS-232 or RS-485 interface devices, data communication speed from 0 -115.2KBPS, three power supply and data traffic lights may direct fault conditions, the support means of communication with RS -232C to RS-422, RS-422 to RS-485 converter.

Parameters£º
¢Å¡¢Interface Features: interface is compatible with EIA / TIA of the RS-232, RS-485/RS-232 Standard
¢Æ¡¢Electrical Interface: RS-232 interface DB9 hole connector   
                        :RS-422/RS-485 interface connector hole
¢Ç¡¢Transmission media: twisted-pair or shielded cable
¢È¡¢Methods of work: Asynchronous half-duplex or full-duplex asynchronous
¢É¡¢Signal instructions: three signal lights TXD, RXD, PWR
¢Ê¡¢Isolation: isolation voltage 3500VRMS 500VDC continuous
¢Ë¡¢Transfer rate£º
       115.2KBPS to 1.2KM
       38.4KBPS to 2.4KM
       600KBPS to 5KM
¢Ì¡¢Protection class£ºRS-232 Interface¡À15KV  ESD Protect RS-422¡¢RS-485 Each line interface 1000W and Lightning Surge Protection
¢Í¡¢Transmission distance£º0¡« 5KM£¨115200¡«96000BPS£©
¢Î¡¢Dimension£º 125mm¡Á 54mm¡Á 25mm
¢Ï¡¢Use of the environment£º -25¡æ to 70¡æ£¬Relative humidity of 5% to 95%

4¡¢Printer  
In theory, the system as long as the chosen printer and computer connections are the normal use, including needle, inkjet, laser, specifically chosen according to customer's existing equipment and needs, but the instrument does not support the laser and inkjet printers, the general Circumstances, the instrument chosen ESPON LQ-300K (+), KX-P1121, KX-P1131

5¡¢Scoreboard  
Receive way RS -232C (TXD), choice of a 3,5,8-inch module type or lattice type. See site information.

6¡¢Weighing Management Software
The company is equipped with a weighing system for vehicles weighing Benui management system is the result of many years of market research in conjunction with several scales professionals and on-site installation, operator feedback, the use of stable and reliable development platform for the production of a weighing management software.




Weighing The Software Has The Following Features£º
¢Ù¡¢Powerful software, high security, such as the weighing data and centralized management, boot automatically after startup, shut down the software can shut down the computer, the system parameters and weighing the random data backup.
¢Ú¡¢Able to fully realize that Taiwan corners adjustment, sub-scale value is set, the sensor's real-time status tracking, display, these functions ensure that body and sensor failures queries.
¢Û¡¢Interface, clear and concise, simple operation, weighing data maintenance, query, statistics, print, backup ranging, short-term training, you can with ease.
¢Ü¡¢Expanded network functionality, network management and sharing can be achieved at the same time, also provides the corresponding interface and hardware equipment in order to achieve the network management and process monitoring functions.

7¡¢Weighing Indicator  
Our company profile is DS1, DS2, XK3190-DS3 digital meter, functional description and instructions for use visit our website:www.china-loadcells.com